110
option button to set the output option.
13) Enter the first page of “Pass/Fail function menu”, press the “Operate”
option button to select “ ”to run the pass/fail test.
Picture 2.13-19
2.13.8 Waveform Recorder
Waveform recorder can record input waveform from CH1, CH2, CH3 and CH4.with a
maximum record length of 2500 frames. This record behavior can also be activated by
the pass/fail test output, which makes this function especially useful to capture abnormal
signals in long term without keeping an eye watching it.
Waveform recorder: Record the waveforms with specified interval.
Table 2-60 Waveform recorder function menu:
Option Setting Instruction
Mode Record
Play Back
Storage
Off
Set Record function menu.
Set Play Back function menu.
Set Storage function menu.
Turn off waveform recorder menu.
Source CH1
CH2
CH3
CH4
P/F-OUT
Select record source channel.
Interval
Set time interval between record frames.
End
Frame
Set max number of record frames.
Operate
Record
Stop
Press to start recording.